* \file
* <!--
* This file is part of BeRTOS.
*
* Bertos is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; either version 2 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, write to the Free Software
* Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA 02110-1301 USA
*
* As a special exception, you may use this file as part of a free software
* library without restriction. Specifically, if other files instantiate
* templates or use macros or inline functions from this file, or you compile
* this file and link it with other files to produce an executable, this
* file does not by itself cause the resulting executable to be covered by
* the GNU General Public License. This exception does not however
* invalidate any other reasons why the executable file might be covered by
* the GNU General Public License.
*
* Copyright 2004, 2005, 2009 Develer S.r.l. (http://www.develer.com/)
*
* -->
*
* \brief Thermo-control driver.
*
* This module implements multiple thermo controls, which is the logic needed to try
* keeping the temperature of a device constant. For this module, a "device" is a black box
* whose temperature can be measured, and which has a mean to make it hotter or colder.
* For instance, a device could be the combination of a NTC (analog temperature reader) and
* a Peltier connected to the same physic block.
*
* This module relies on a low-level driver to communicate with the device (implementation
* of the black box). This low-level driver also controls the units in which the temperature
* is expressed: thermo control treats it just as a number.
*
*
* \author Giovanni Bajo <rasky@develer.com>
* \author Francesco Sacchi <batt@develer.com>
* \author Daniele Basile <asterix@develer.com>
*
* $WIZ$ module_name = "thermo"
* $WIZ$ module_depends = "timer", "ntc"
* $WIZ$ module_configuration = "bertos/cfg/cfg_thermo.h"
* $WIZ$ module_hw = "bertos/hw/hw_thermo.h", "bertos/hw/thermo_map.h"
*/
#ifndef DRV_THERMO_H
#define DRV_THERMO_H
#include "hw/thermo_map.h"
#include <drv/ntc.h>
#include <drv/timer.h>
typedef uint8_t thermostatus_t;
/**
* Set the target temperature at which a given device should be kept.
*
* \param dev Device
* \param temperature Target temperature
*/
void thermo_setTarget(ThermoDev dev, deg_t temperature);
/**
* Start thermo control for a certain device \a dev and stop it after
* \a on_time msec.
*/
void thermo_timer(ThermoDev dev, mtime_t on_time);
/** Start thermo control for a certain device \a dev */
void thermo_start(ThermoDev dev);
/** Stop thermo control for a certain device \a dev */
void thermo_stop(ThermoDev dev);
/** Clear errors for channel \a dev */
void thermo_clearErrors(ThermoDev dev);
/** Return the status of the specific \a dev thermo-device. */
thermostatus_t thermo_status(ThermoDev dev);
/**
* Return the current temperature of a device currently under thermo
* control.
*
* \param dev Device
* \return Current temperature (Celsius degrees * 10)
*/
deg_t thermo_readTemperature(ThermoDev dev);
void thermo_init(void);