This is at the top of the license header.
It prevents the code from being processed but doesn't
actually impact the license terms in any way.
Change-Id: Ic91f2400f9694056b6f06fa43d1074411d6c6262
ThroughPut numbers in rate selection table were not based on
expected definition from Minstrel's docs. Rather, was based
on 1200 byte packets and transmit time included SIFS time
inflating #s.
Due to issues we are pulling the showing of tunnels untill we can better detect them.
We are also pulling dtdlink as all AREDN nodes should have dtdlink enabled.
Add the NLQ to the remote neighbors display so users can see both directions of the path from the mesh status screen.
ETX is dependent upon both directions of the path.
Create get_interface which will lookup in the current uci network config the realname for the logical interface name.
When the interface is not found it will fall back to a hard coded list.
Configure the UI to use the new get_interface function.
Since a large number of the BBHNDev team has decided to create firmware fully independent of the BBHN Project the decision has been made to rebrand the firmware to differentiate from the origional BBHN work.
We would like to thank all those whom have worked on the BBHN firmware over the years and all those who continue to work on the firmware under AREDN(TM).
Program went GPLv3 last year but license text was never added to files
Default text to give credit to David as he is listed in all commits and to reference the BBHN Austin team at the same time as they were part of the group of HAM's that started this project.
mid hostname entries are only created on remote nodes and are not created on the local node (by design of nameservice module)
In order to allow links on remote nodes olsr status screens and potentionaly other locations to resolve correctly we must add a hostname for the dtdlink interface into the name service beacons.
In addtion we need to ensure the UI looks at these links instead.
This feature will need to be looked at for long in the mesh status screen to find a better method to display these connections.
ref BBHN->ticket:47
fixes BBHN->ticket:1
Units will show:
Yellow banner for devices we have not yet tested.
Red banner for devices we have confirmed do not work.
Relies on what Ubiquiti calls the board.sysid which is the
value of subsystem_device on the first PCI device.
Includes removing files that are provided by packages instead
of being embedded as binaries.
Changes made for UBNT hardware AND for newer base openwrt (Backfire)