Commit Graph

11 Commits

Author SHA1 Message Date
Joe Ayers f134465edb aredn: add auto distance setting option
contributing author lua code: dman776 <dman776@gmail.com>
2019-05-03 19:17:14 -07:00
Joe Ayers a399623140 Revert "aredn: enable ath9k auto distance capability (#367)"
This reverts commit d5be7814b3.
Auto Distance is not ready for a release and will be
reintroduced afterwards. Added logic to reset '0' distance
to 60km so tower nodes will continue to respond after
upgrade if running the experimental auto distance
2019-03-21 21:30:48 -07:00
Jason 30069e5ade Format code 2018-07-20 20:34:44 -08:00
Conrad Lara - KG6JEI e5fc675cfc bugfix: OTA Upgrade fails with static WAN.
Wan interface settings are not correctly copied
over after an OTA causing node-setup to fail
when using a static WAN ip.

fixes->AREDN🎫226

Change-Id: I494c05bc0047f1db4c1452cbdbd8e236f4fcd945
2017-04-20 12:41:09 -07:00
Conrad Lara - KG6JEI 1b65f8a3ad bugfix: UI allows enabling mesh_gw when wan disabled or nat mode
Mesh nodes would need a significant amount of configuration
including some operational checks everytime an interface comes up
to be able to handle this.

The more sane method is to only allow a node to be a mesh_gw when
the WAN port is utilized and the node is in DIRECT mode.

This changes the UI to prevent this setup from being allowed.

fixes AREDN->ticket:184

Change-Id: I1a1289bc914a349149f5842812dbebc0a70442f7
2016-09-20 23:09:03 -07:00
AE6XE d4b7617e03 remove non-mesh modes from setup options
fixes AREDN->ticket:175

Change-Id: I7517df178a5ce82ef79ec4af844932fe6569d8da
2016-08-07 21:38:18 +00:00
Conrad Lara - KG6JEI fad8a43974 cleanup: Resolve "used once" warning. 2016-03-06 23:38:00 -08:00
Conrad Lara - KG6JEI 854a536629 bugfix: Settings set to 0(off/disabled) are not copied over during OTA.
Some settings would not copy correctly and would fall back to the config default due to faulty if checks logic when the value was set to 0 ending up in if(0) checks.
2015-11-15 10:59:17 -08:00
Conrad Lara - KG6JEI ac93a0346f feature: migrate scripts to use get_interface
nvram-setup may be the only script we have to worry about as it may call configs for interfaces that do not exist in the current mode.

By default get_interface will return a static mapping when it can't find an active config entry meaning that eventually get_interface will need an update routine to pull out of local running config

The lack of this update routine should be acceptable for now as we have no GUI for users to change the mapping.
2015-03-24 23:41:51 -07:00
Conrad Lara - KG6JEI 078ab54f06 bugfix: sysupgrade : OLSRD and LAN interface do not work after sysupgrade
Variables were not being being synced to _setup because they do not exist in _setup.default so we need to manually sync them over.
2015-03-23 17:25:18 -07:00
Conrad Lara - KG6JEI cccf5a2ad7 feature: Add the ability to upgrade in place and keep settings.
By checking the "Keep Settings" box the node will run sysupgrade instead of mtd. Core settings are stored between installs and the _setup files are updated by pulling in missing items from the _setup.default files.
2014-11-12 21:25:41 -08:00