Fix initialization of `_device_list_id_gen` (#14914)
On startup, the `_device_list_id_gen` stream id generator is initialized using the maximum stream id seen in a list of tables. When we started populating the `device_list_remote_pending` table in #13913, we forgot to add it to the aforementioned list of tables, so the stream id generator can hand out old stream ids after a restart. The end result is that Synapse can fail to handle device list update EDUs after a restart when a partial state join is in progress. Add the `device_list_remote_pending` table to the list of tables to consider when initializing the `_device_list_id_gen` stream id generator. Signed-off-by: Sean Quah <seanq@matrix.org>
This commit is contained in:
parent
f51035bc87
commit
cf66d712c6
|
@ -0,0 +1 @@
|
||||||
|
Faster joins: Fix a bug introduced in Synapse 1.69 where device list EDUs could fail to be handled after a restart when a faster join sync is in progress.
|
|
@ -99,6 +99,7 @@ class DeviceWorkerStore(RoomMemberWorkerStore, EndToEndKeyWorkerStore):
|
||||||
("user_signature_stream", "stream_id"),
|
("user_signature_stream", "stream_id"),
|
||||||
("device_lists_outbound_pokes", "stream_id"),
|
("device_lists_outbound_pokes", "stream_id"),
|
||||||
("device_lists_changes_in_room", "stream_id"),
|
("device_lists_changes_in_room", "stream_id"),
|
||||||
|
("device_lists_remote_pending", "stream_id"),
|
||||||
],
|
],
|
||||||
is_writer=hs.config.worker.worker_app is None,
|
is_writer=hs.config.worker.worker_app is None,
|
||||||
)
|
)
|
||||||
|
|
Loading…
Reference in New Issue